How to Use Poly Ferric Sulfate (PFS) in Water Treatment
Overview
Poly Ferric Sulfate (PFS) is a high-performance inorganic coagulant with ≥ 19% Fe content. It outperforms PAC in cold water (< 5°C), high-color applications, and heavy metal co-removal. PFS produces denser flocs with faster settling. Working pH range: 4.0–11.0.
Preparation & Dissolution
PFS is supplied as a dark reddish-brown liquid (specific gravity ~1.45). No dissolution needed — dose directly or dilute to 5–10% working solution.
For solid PFS (less common):
- Fill tank with clean water
- Add PFS granules slowly with agitation
- Stir 20–30 minutes
- Working solution concentration: 5–10%
Equipment: PVC, HDPE or FRP tanks and piping. Avoid stainless steel 304 (chloride stress corrosion). Metering pump with anti-siphon valve.
Dosing Guide
| Application | Typical Dose (as product) | Notes |
|---|---|---|
| Municipal wastewater | 30–80 ppm | Better color removal than PAC |
| Cold water (< 5°C) | 20–50 ppm | Does not slow down like PAC in cold |
| Textile wastewater | 80–150 ppm | Superior for reactive dye removal |
| Heavy metal co-removal | 50–150 ppm | Fe(OH)₃ co-precipitates Cu, Zn, Pb |
| Phosphorus removal | 10–30 ppm as Fe | Fe:P molar ratio 1.5–2.5:1 |
Application Procedure
- Measure raw water turbidity, color, pH, temperature, and target metals
- Set metering pump to target dose
- Inject at flash mix zone with vigorous agitation (G > 300 s⁻¹) for 1 minute
- Slow mix at 30–50 s⁻¹ for 15–20 minutes
- Settle in clarifier (HRT 2–4 hours)
- Monitor settled water quality
- Check for iron residual in effluent — if yellowish tint, dose is too high
Monitoring & Control
| Parameter | Frequency | Target |
|---|---|---|
| Settled water turbidity | Every 30 min | < 5 NTU |
| Effluent color | Hourly | < 40 Pt-Co |
| pH after dosing | Hourly | Note: PFS depresses pH more than PAC |
| Iron residual | Daily | < 0.3 mg/L |
| Phosphate (if P removal) | Daily | < 0.5 mg/L TP |
Common Mistakes
- Forgetting pH impact: PFS drops pH more than PAC (0.5–1.5 units). May need NaOH co-dosing for low-alkalinity water.
- Iron staining: Overdosing causes yellowish effluent from residual Fe³⁺. Reduce dose or add polymer to settle iron flocs.
- Mixing with phosphonate inhibitors: PFS reacts with HEDP/ATMP, reducing both coagulant and inhibitor effectiveness. Dose at separate injection points.
- Using in drinking water without monitoring: Iron residual must be < 0.3 mg/L to avoid taste/color issues.
Storage & Handling
- Shelf life: 12 months (liquid)
- Temperature: Store above 0°C. PFS may crystallize below -5°C but can be reconstituted by warming to 20°C with agitation.
- Container: HDPE, PVC, FRP. Avoid bare metals.
- Safety: Acidic (pH 2–3). Strong oxidizer hazard if concentrated. Wear acid-resistant PPE. Stains skin and clothing brown — wash immediately.